kerfmaster -- floor packet, part-list sheet program

O33487

component131400 + 3 more · part-list delivery v2 · delivered 2026-10-08 15:00:02

Material: Aluminum,0.75 (post Aluminum,0.75)
Machine: GX 10K
Sheet: 120" x 60" · 1 sheet, ONE PROGRAM PER SHEET, part-by-part by construction
Sheet 1: O33487 -- 7 parts, 57 boundaries, 0 red / 46 yellow warnings in the file
component131400_117.dxf: asked 1, filled 1
component131400.dxf: asked 1, filled 1
mast_mount_backing_pad-106536.dxf: asked 3, filled 3
side_plate_0001.dxf: asked 2, filled 2
Usage: 7.1% -- 511.51 in² net part area over 1 x 7200 in² sheet (true outlines, never bounding boxes)
Part map: the numbered CSV names each placement's sheet, program and part number ("placement 001 is ...")
Slugs: 54 numbered slugs -- report failures by slug number (see the CSV).
Time estimate: PENDING -- no estimator exists yet; never invented.

Material record: Material Aluminum · Thickness 0.750 IN
the job card's traits -- the same record rides as comments in the posted program header.

46 yellow warnings + 46 audit anomalies -- called out in the program text.

Sheet 1 of 1 -- O33487, 7 parts

The customer sheet reads, verbatim (customer.html in this delivery set):

Machine-side changes happen on the control; this packet is paper truth for the floor. kerfmaster.